This document gives the definitions and specifies the minimum requirements for injection moulded, extruded, compression moulded and thermoformed thermoplastics cuboid shaped boxes, including integral components, used in underground systems for retention, detention, storage and transportation of non-potable water (e.g. storm water) and manufactured from polyethylene (PE), polypropylene (PP) or unplasticized polyvinylchloride (PVC-U). The boxes are intended for buried underground use, e.g. in landscape, pedestrian or vehicular traffic areas. In the case of retention and detention systems, the main purpose of the boxes is to retain water, for later infiltration in the ground or for later use in non-potable applications (irrigation, cleaning, sanitary facilities, etc.) or to retain water during a storm, transferring it in a controlled way to the public storm water network. Applications include commercial, residential, agricultural and highway drainage, including installation under parking lots and roadways. Product performance is determined by a combination of material specification, product design and manufacturing process. A box can either be factory-assembled or site-assembled from different components. The boxes are intended to be used as elements in a modular system where the manufacturer has provided a clearly documented method specifying how the components are assembled to create a complete retention, detention, storage and transportation system. The boxes are installed as one or more horizontal layers on a firm foundation and embedded with fill around and above the complete system. NOTE Non-load bearing component(s) can be manufactured by various methods (e.g. extrusion, injection moulding, rotational moulding, compression moulded, thermoforming and low-pressure injection moulding) and are not within the scope of this document.

  • Standard
    16 pages
    English language
    sale 15% off
  • Draft
    17 pages
    English language
    sale 15% off
  • Amendment
    14 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    11 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document, in conjunction with ISO 11298‑1, specifies requirements and test methods for cured-in-place pipes and fittings used for the renovation of water supply networks, which transport water intended for human consumption, including raw water intake pipelines.
It applies to independent (fully structural, class A) and interactive (semi structural, class B) pressure pipe liners, as defined in ISO 11295, which do not rely on adhesion to the existing pipeline. It applies to the use of various thermosetting resin systems, in combination with compatible fibrous carrier materials, reinforcement, and other process-related plastics components (see 5.1).
It does not include requirements or test methods for resistance to cyclic loading or the pressure rating of CIPP liners where passing through bends, which are outside the scope of this document.
It is applicable to cured-in-place pipe lining systems intended to be used at a service temperature of up to 25 °C.
NOTE   For applications operating at service temperatures greater than 25 °C, guidance on re-rating factors can be supplied by the system supplier.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    8 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off
  • Draft
    8 pages
    English language
    sale 15% off
  • Draft
    9 pages
    French language
    sale 15% off

This document specifies the principles of design, sizing, installation, identification, commissioning and maintenance of greywater systems with the purpose of use of greywater on-site.
It applies preferably for the use of treated greywater for:
-   WC flushing;
-   garden watering;
-   laundry;
-   cleaning purposes.
This document also specifies the minimum requirements for greywater systems.
Excluded from the scope of this document are:
-   the use as drinking water and for food preparation;
-   the use for personal hygiene purposes;
-   direct reuse systems without treatment;
-   product design for specific system components;
-   industrial effluents;
-   heat recovery and cooling demands.
NOTE   Conformity with this document does not exempt from compliance with the obligations arising from local or national regulations.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    33 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Amendment
    9 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    6 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document gives the recommended practise for underground open trench installation and commissioning of thermoplastics piping systems to be used for the conveyance of water under pressure (in addition to EN 805) and for the discharge of wastewater under gravity (in addition to EN 1610) .
In the field of non-pressure underground drainage and sewerage this is reflected in the marking of products by application code "U" and "UD":
-   outside the building structure (U);
-   both buried in ground within the building structure (application area code "D") and outside the
building (application area code "UD").
This document covers also installation and/or connections to valves, manholes, inspection chambers, gullies and other ancillary components in piping systems.
NOTE 1   Code of practise for pipelines for gas supply is covered by EN 12007-series [21].
NOTE 2   Recommended practices for installation of plastic piping systems for soil and waste discharge within the building structure is covered by CEN/TR 13801 [12].
NOTE 3   Practices for underground installation of rainwater infiltration and storage attenuation systems are covered by CEN/TR 17179 [13].
NOTE 4   It is assumed that additional recommendations and/or requirements are detailed in the individual product standards.
NOTE 5    If non-plastic components are part of the plastic system the manufacturer's instructions should be taken into account.
Requirements and instructions concerning commissioning of systems can be found in EN 805 and EN 1610 and the relevant national and/or local regulations. This document gives specific additional recommendations for commissioning relevant for plastic piping systems.
Attention is drawn to any relevant local and/or national regulations (e.g. health, safety and hygienic requirements).

  • Technical specification
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard, in conjunction with ISO 11298-1, specifies requirements and test methods for cured-in-place pipes and fittings used for the renovation of underground water supply networks. It applies to the use of various thermosetting resin systems, in combination with compatible fibrous carrier materials and other process-related plastics components.

  • Standard
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    44 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document provides examples of good practices in stormwater management related to ISO 24536 and information on standards and guidelines used in various countries.

  • Technical report
    80 pages
    English language
    sale 15% off
  • Technical report
    86 pages
    French language
    sale 15% off
  • Draft
    80 pages
    English language
    sale 15% off

This document, in conjunction with ISO 11298‑1, specifies requirements and test methods for cured-in-place pipes and fittings used for the renovation of water supply networks, which transport water intended for human consumption, including raw water intake pipelines. It applies to independent (fully structural, class A) and interactive (semi structural, class B) pressure pipe liners, as defined in ISO 11295, which do not rely on adhesion to the existing pipeline. It applies to the use of various thermosetting resin systems, in combination with compatible fibrous carrier materials, reinforcement, and other process-related plastics components (see 5.1). It does not include requirements or test methods for resistance to cyclic loading or the pressure rating of CIPP liners where passing through bends, which are outside the scope of this document. It is applicable to cured-in-place pipe lining systems intended to be used at a service temperature of up to 25 °C. NOTE For applications operating at service temperatures greater than 25 °C, guidance on re-rating factors can be supplied by the system supplier.

  • Standard
    39 pages
    English language
    sale 15% off
  • Standard
    42 pages
    French language
    sale 15% off
  • Draft
    38 pages
    English language
    sale 15% off
  • Draft
    42 pages
    French language
    sale 15% off

This European Standard specifies the principles of design, sizing, installation, identification, commissioning and maintenance of greywater systems with the purpose of use of greywater on-site.
It applies preferably for the use of treated greywater for:
-   WC flushing;
-   garden watering;
-   laundry;
-   cleaning purposes.
This European Standard also specifies the minimum requirements for greywater systems.
Excluded from the scope of this European Standard are:
-   the use as drinking water and for food preparation;
-   the use for personal hygiene purposes;
-   direct reuse systems for external use e. g. garden watering;
-   product design for specific system components;
-   industrial effluents;
-   heat recovery and cooling demands.
NOTE   Conformity with this European Standard does not exempt from compliance with the obligations arising from local or national regulations.

  • Standard
    30 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    33 pages
    French language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Standard
    1 page
    English language
    sale 15% off
  • Standard
    1 page
    French language
    sale 15% off
  • Draft
    1 page
    English language
    sale 15% off
  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    3 pages
    English language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off
  • Standard
    3 pages
    French language
    sale 15% off
  • Draft
    3 pages
    English language
    sale 15% off
  • Standard
    2 pages
    English language
    sale 15% off
  • Standard
    2 pages
    French language
    sale 15% off
  • Draft
    2 pages
    English language
    sale 15% off

This document provides guidance to stormwater management authorities and relevant stakeholders on both structural and non-structural stormwater management approaches. The guidance includes consideration of relevant policies, planning, design criteria and implementation processes for stormwater management, and performance evaluation. This document can be applied to new stormwater systems and to the extension or improvement of existing systems for both fully separated and combined storm and sanitary sewers. This document is applicable to stormwater sewer systems as well as combined sewer systems. This document is not applicable to sanitary sewer systems.

  • Standard
    54 pages
    English language
    sale 15% off
  • Standard
    58 pages
    French language
    sale 15% off

This document specifies the general aspects of polyethylene (PE) compounds for the manufacture of pressure pipes and fittings (mains and service pipes) for buried or above ground applications, intended for the conveyance of: — water for human consumption; — raw water prior to treatment; — drainage and sewerage under pressure; — vacuum sewer systems; — water for other purposes. This document also specifies the test parameters and requirements for the test methods referred to in this document. In conjunction with other parts of the ISO 4427 series, this document is applicable to PE pipes and fittings, their joints and to joints with components made of PE and other materials, intended to be used under the following conditions: a) a maximum allowable operating pressure (PFA) up to and including 25 bar[1]; b) an operating temperature of 20 °C as the reference temperature. NOTE 1 For other operating temperatures, guidance is given in Annex A. The ISO 4427 series covers a range of maximum allowable operating pressures and gives requirements concerning colours. NOTE 2 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and installation practices or codes. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

  • Standard
    17 pages
    English language
    sale 15% off

This document specifies the pipes made from polyethylene (PE) for buried or above ground applications, intended for the conveyance of: — water for human consumption; — raw water prior to treatment; — drainage and sewerage under pressure; — vacuum sewer systems; — water for other purposes. NOTE 1 The intended uses include sea outfalls, laid in water and pipes suspended below bridges. Pipes complying with this document are not intended for the transport of water intended for human consumption in contaminated soils unless special consideration has been taken. NOTE 2 For example, ISO 21004 provides an alternative solution for use in contaminated soils. See Reference [3] in the Bibliography. This document specifies three types of pipe: — PE pipes (outside diameter dn), including any identification stripes; — PE pipes with co-extruded layers on either or both the outside and/or inside of the pipe (total outside diameter dn) where all layers have the same MRS rating; — PE pipes (outside diameter dn) having a peelable and contiguous thermoplastics additional layer on the outside of the pipe ("coated pipe"). This document also specifies the test parameters for the test methods referred to in this document. In conjunction with the other parts of the ISO 4427 series, this document is applicable to PE pipes, their joints and to joints with components made of PE and other materials, intended to be used under the following conditions: a) a maximum allowable operating pressure (PFA) up to and including 25 bar[1]; b) an operating temperature of 20 °C as the reference temperature. NOTE 3 For other operating temperatures, guidance is given in ISO 4427‑1:2019, Annex A. This document covers a range of maximum allowable operating pressures and gives requirements concerning colours. NOTE 4 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and installation practices or codes. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

  • Standard
    20 pages
    English language
    sale 15% off

This document specifies the characteristics of the fitness for purpose of pipes and/or fittings assemblies made from polyethylene (PE) for buried or above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and water for other purposes. NOTE 1 The intended uses include sea outfalls, laid in water and pipes suspended below bridges. NOTE 2 This document is intended to be only used by the product manufacturer to assess the performance of components according to ISO 4427‑2 and/or ISO 4427‑3 when joined together under normal and extreme conditions. It is not intended for on-site testing of pipe systems. This document also specifies the test parameters for the test methods referred to in this document. In conjunction with the other parts of the ISO 4427 series, this document is applicable to PE pipes, fittings, their joints and to joints with components of PE and other materials, intended to be used under the following conditions: a) a maximum allowable operating pressure (PFA) up to and including 25 bar[1]; b) an operating temperature of 20 °C as the reference temperature. NOTE 3 For other operating temperatures, guidance is given in ISO 4427‑1: 2019, Annex A. The ISO 4427 series covers a range of maximum allowable operating pressures and gives requirements concerning colours. [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

  • Standard
    9 pages
    English language
    sale 15% off

This document specifies the fittings made from polyethylene (PE) for buried or above ground applications, intended for the conveyance of water for human consumption, raw water prior to treatment, drainage and sewerage under pressure, vacuum sewer systems, and water for other purposes. NOTE 1 The intended uses include sea outfalls, laid in water and connection between pipes suspended below bridges. This document also specifies the test parameters for the test methods referred to in this document. In conjunction with the other parts of the ISO 4427 series, this document is applicable to PE fittings, to joints with components of PE or other materials, intended to be used under the following conditions: a) a maximum allowable operating pressure (PFA) up to and including 25 bar[1]; b) an operating temperature of 20 °C as the reference temperature. NOTE 2 For other operating temperatures, guidance is given in ISO 4427‑1:2019, Annex A. This document covers a range of maximum allowable operating pressures and gives requirements concerning colours. NOTE 3 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and installation practices or codes. This document is applicable to fittings of the following types: 1. fusion fittings; a. electrofusion fittings; b. spigot end fittings (for butt fusion using heated tools and electrofusion socket fusion); c. socket fusion fittings (see Annex A); 2. mechanical fittings; a. compression fittings; b. flanged fittings; 3. fabricated fittings (see Annex B). [1] 1 bar = 0,1 MPa = 105 Pa; 1 MPa = 1 N/mm2.

  • Standard
    35 pages
    English language
    sale 15% off

This document specifies the requirements for the structural design of water supply pipelines, drains
and sewers, and other water industry pipelines, whether operating at atmospheric, greater or lesser
pressure.
In addition, this document gives guidance on the application of the nationally established methods of
design declared by and used in CEN member countries at the time of preparation of this document.
This guidance is an important source of design expertise, but it cannot include all possible special cases,
in which extensions or restrictions to the basic design methods may apply.
Since in practice precise details of types of soil and installation conditions are not always available at
the design stage, the choice of design assumptions is left to the judgement of the engineer. In this
connection the guide can only provide general indications and advice.
This document specifies the requirements for structural design and indicates the references and the
basic principles of the nationally established methods of design (see Annexes A and B).

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document, in conjunction with ISO 11298‑1, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of water supply networks, which transport water intended for human consumption, including raw water intake pipelines.
It applies to pipes and fittings, as manufactured, as well as to the installed lining system. It is applicable to polyethylene (PE) pipes of either solid wall single layer or co-extruded layer construction, which is reduced in the factory or on site to provide a close-fitting independent or interactive pressure pipe liner, as well as associated fittings and joints for the construction of the lining system. It is not applicable to PE coated pipes having a peelable, contiguous, thermoplastic additional layer on the outside of the pipe.
It is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of 20 °C as the reference temperature.
NOTE       For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see ISO 4427‑1:2007, Annex A.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 22391 gives guidance for the assessment of conformity of materials, products, and assemblies in accordance with the applicable part(s) of ISO 22391 intended to be included in the manufacturer’s quality plan as part of the quality management system and for the establishment of certification procedures.
In conjunction with the other parts of ISO 22391 (see Foreword), this Technical Specification is applicable to polyethylene of raised temperature resistance (PE-RT) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application (see Table 1 of ISO 22391:2009).

  • Technical specification
    25 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Draft
    26 pages
    German language
    sale 10% off
    e-Library read for
    1 day

This document gives requirements and guidance for the assessment of conformity of materials, products, and assemblies in accordance with the applicable part(s) of ISO 22391 intended to be included in the manufacturer's quality plan as part of the quality management system and for the establishment of certification procedures. NOTE In order to help the reader, a basic test matrix is given in Annex A. In conjunction with the other parts of ISO 22391 (see Foreword), this document is applicable to polyethylene of raised temperature resistance (PE-RT) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not intended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 22391-1:2009, Table 1).

  • Technical specification
    16 pages
    English language
    sale 15% off

This document, in conjunction with ISO 11298-1, specifies requirements and test methods for close-fit
lining systems intended to be used for the renovation of water supply networks, which transport water
intended for human consumption, including raw water intake pipelines.
It applies to pipes and fittings, as manufactured, as well as to the installed lining system. It is applicable
to polyethylene (PE) pipes of either solid wall single layer or co-extruded layer construction, which is
reduced in the factory or on site to provide a close-fitting independent or interactive pressure pipe liner,
as well as associated fittings and joints for the construction of the lining system. It is not applicable to
PE coated pipes having a peelable, contiguous, thermoplastic additional layer on the outside of the pipe.
It is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of
20 °C as the reference temperature.
NOTE For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see
ISO 4427-1:2007, Annex A.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 11298-1:2018 specifies the requirements and test methods for plastics piping systems intended to be used for the renovation of underground water supply networks. It is applicable to pipes and fittings, as manufactured, as well as to the installed lining system. It is not applicable to the existing pipeline or any non-structural sprayed coatings or annular filler.
ISO 11298-1:2018 gives the general requirements common to all relevant renovation techniques.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document, in conjunction with ISO 11298‑1, specifies requirements and test methods for close-fit lining systems intended to be used for the renovation of water supply networks, which transport water intended for human consumption, including raw water intake pipelines. It applies to pipes and fittings, as manufactured, as well as to the installed lining system. It is applicable to polyethylene (PE) pipes of either solid wall single layer or co-extruded layer construction, which is reduced in the factory or on site to provide a close-fitting independent or interactive pressure pipe liner, as well as associated fittings and joints for the construction of the lining system. It is not applicable to PE coated pipes having a peelable, contiguous, thermoplastic additional layer on the outside of the pipe. It is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of 20 °C as the reference temperature. NOTE For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see ISO 4427‑1:2007, Annex A.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    16 pages
    French language
    sale 15% off

ISO 11298-2:2018, read in conjunction with ISO 11298-1, specifies requirements and test methods for pipes and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of underground water supply networks. It is applicable to PE pipes of three different types:
-      PE solid wall single layered pipes (nominal outside diameter, dn), including any identification stripes;
-      PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex A, where all layers have the same MRS rating;
-      PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe ("coated pipe"); see Annex A.
In addition, ISO 11298-2:2018 covers
-      jointing of pipe lengths by means of butt fusion, and
-      fabricated and injection-moulded fittings made of PE.
ISO 11298-2:2018 is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of 20 °C as the reference temperature.
NOTE       For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see ISO 4427-1:2007, Annex A.

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This European Standard specifies the requirements and gives recommendations for the design, sizing, installation, identification, commissioning and maintenance of rainwater harvesting systems for the use of rainwater on-site as non-potable water. This European Standard also specifies the minimum requirements for these systems.
Excluded from the scope of this European Standard are:
- the use as drinking water and for food preparation;
- the use for personal hygiene purposes;
- decentralized attenuation;
- infiltration.
NOTE   Conformity with the standard does not exempt from compliance with the obligations arising from local or national regulations.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This document specifies the requirements and test methods for plastics piping systems intended to be
used for the renovation of underground water supply networks. It is applicable to pipes and fittings, as
manufactured, as well as to the installed lining system. It is not applicable to the existing pipeline or
any non-structural sprayed coatings or annular filler.
This document gives the general requirements common to all relevant renovation techniques.

  • Standard
    26 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This International Standard, read in conjunction with Part 1, specifies requirements and test methods for pipes and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of underground water supply networks. It is applicable to PE pipes of three different types:
-   PE solid wall single layered pipes (nominal outside diameter, dn ), including any identification stripes;
-   PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex A, where all layers have the same MRS rating;
-   PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe (“coated pipe”), see Annex A.
In addition it covers:
-   jointing of pipe lengths by means of butt fusion;
-   fabricated and injection-moulded fittings made of PE;

  • Standard
    18 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 11298-1:2018 specifies the requirements and test methods for plastics piping systems intended to be used for the renovation of underground water supply networks. It is applicable to pipes and fittings, as manufactured, as well as to the installed lining system. It is not applicable to the existing pipeline or any non-structural sprayed coatings or annular filler. ISO 11298-1:2018 gives the general requirements common to all relevant renovation techniques.

  • Standard
    16 pages
    English language
    sale 15% off
  • Standard
    17 pages
    French language
    sale 15% off

This European Standard specifies the design, sizing, installation, identification, commissioning and maintenance of rainwater harvesting systems for the use of rainwater on-site as a substitute for potable water. This standard also specifies the minimum requirements for these systems.
Excluded from the scope of this standard are:
-   the use as drinking water,
-   decentralized attenuation,
-   infiltration.
NOTE   Conformity with the standard does not exempt from compliance of the obligations arising from local or national regulations.

  • Standard
    35 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 11298-2:2018, read in conjunction with ISO 11298-1, specifies requirements and test methods for pipes and fittings which are part of plastics piping systems installed as continuous pipes in the renovation of underground water supply networks. It is applicable to PE pipes of three different types: - PE solid wall single layered pipes (nominal outside diameter, dn), including any identification stripes; - PE pipes with co-extruded layers on either or both the outside and inside of the pipe (total outside diameter, dn), as specified in Annex A, where all layers have the same MRS rating; - PE coated pipes (outside diameter, dn) having a peelable, contiguous, thermoplastics additional layer on the outside of the pipe ("coated pipe"); see Annex A. In addition, ISO 11298-2:2018 covers - jointing of pipe lengths by means of butt fusion, and - fabricated and injection-moulded fittings made of PE. ISO 11298-2:2018 is applicable to PE pipes, fittings and assemblies intended to be used at an operating temperature of 20 °C as the reference temperature. NOTE For applications operating at constant temperatures greater than 20 °C and up to 40 °C, see ISO 4427-1:2007, Annex A.

  • Standard
    9 pages
    English language
    sale 15% off
  • Standard
    9 pages
    French language
    sale 15% off

ISO 21307:2017 establishes general principles regarding the procedure used in the construction and quality assessment of butt fusion jointing of polyethylene (PE) piping system components specified in accordance with relevant ISO standards. These components are installed in accordance with the relevant codes of practice, national regulations or industry guidance. Specifically, this document specifies three butt fusion jointing procedures for PE pipes and fittings. These are: - single low-pressure fusion jointing procedure; - dual low-pressure fusion jointing procedure; - single high-pressure fusion jointing procedure. ISO 21307:2017 takes into consideration the materials and components used, the fusion jointing procedure and equipment and the quality assessment of the completed joint. It can be applied in conjunction with appropriate national regulations and standards.

  • Standard
    16 pages
    English language
    sale 15% off

ISO 9349:2017 specifies the requirements and test methods applicable to preinsulated ductile iron pipes, fittings, accessories and their joints for the construction of pipelines (or parts thereof): - to convey water (e.g. potable water), wastewater and other liquids; - to be operated with or without pressure; - to be installed below or above ground; - to limit temperature variations of the conveyed fluids. These pipelines are mainly used to prevent the water to be conveyed from freezing by providing external insulation. NOTE 1 In this document, all pressures are relative pressures expressed in bars[1]). ISO 9349:2017 gives, in addition to the specifications of the existing International Standards for the conveying ductile iron pipes and fittings, specifications for materials, dimensions and tolerances, mechanical and thermal properties of the thermal insulation layer and external casing of preinsulated ductile iron pipes, fittings and accessories. ISO 9349:2017 covers preinsulated ductile iron pipes, fittings and accessories of a size range extending from DN 60 to DN 600 inclusive, which are as follows: - manufactured with socketed, flanged or spigot ends for jointing by means of various types of gaskets which are not within the scope of this document; - preinsulated in the works (excluding on site application of the insulation layer and/or the casing); - normally delivered internally and externally coated; - intended for fluid temperatures from 0 °C to 50 °C, excluding frost. NOTE 2 Other applications are possible by agreement between manufacturer and purchaser. [1]) 100 kPa = 1 bar.

  • Standard
    7 pages
    English language
    sale 15% off
  • Standard
    7 pages
    French language
    sale 15% off

This standard specifies the requirements for pipes, fittings, brackets and the system of unplasticized poly(vinyl chloride) (PVC-U) intended for use as above-ground external rainwater downpipes.
It also specifies the requirements for metallic brackets.
It specifies both solid wall pipes and fittings, (i.e. product manufactured from a single layer), as well as solid wall multi-layer pipes.
Pipes can be used in conjunction with fittings and brackets of acrylic materials provided these polymers meet the performance requirements of this standard.
It also specifies the test parameters for the test methods referred to in this standard.
These products are usually used in conjunction with gutters conforming to EN 607[1]. They are not intended for use with products conforming to EN 612[2].
It is applicable to PVC-U rainwater systems of circular, square, rectangular or any other shape with sealed (rubber ring or solvent cement) or unsealed joints.
This standard covers a range of pipes and fittings sizes.
NOTE 1    It is the responsibility of the purchaser or specifier to make the appropriate selections from the size range to take into account their particular requirements and any relevant national regulations and installation practices or codes.
NOTE 2   The term "rainwater" in this standard is used also to encompass "surface water" run-off from buildings.

  • Standard
    34 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO/TR 4191:2014 gives recommended practices for installation of unplasticized poly(vinyl chloride) (PVC-U) and oriented unplasticized poly(vinyl chloride) (PVC-O) pipes, fittings, valves, and ancillaries when used in piping systems conveying water under pressure. The recommendations are intended to give practical guidance of design and installation of piping systems incorporating pipes, fittings, valves, and ancillary equipment made from PVC materials and used for the following purposes: water mains and services buried in ground, waste water under pressure, and conveyance of water above ground for both outside and inside buildings, for the supply of water under pressure at approximately 20 °C (cold water) intended for human consumption and for general purposes. ISO/TR 4191:2014 is also applicable to components for the conveyance of water up to and including 45 °C. For temperatures between 25 °C and 45 °C, Figure 1 of ISO 1452‑2:2009 applies. In addition, recommendations are given for the connection to fittings, valves, and ancillary equipment made from materials other than PVC.

  • Technical report
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day
  • Technical report
    44 pages
    English language
    sale 15% off
  • Draft
    49 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 1452-3:2009 specifies the characteristics of fittings made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to.
In conjunction with ISO 1452-1, ISO 1452-2 and ISO 1452-5, it is applicable to PVC‑U fittings and to joints with components of PVC‑U, other plastics and non-plastics materials intended to be used for the following:
- water mains and services buried in the ground;
- conveyance of water above ground for both outside and inside buildings;
- buried and above ground drainage and sewerage under pressure.
It is applicable to fittings in piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to components for the conveyance of water and waste water up to and including 45 °C.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 1452-5:2009 specifies the characteristics for the fitness for purpose of unplasticized poly(vinyl chloride) (PVC‑U) piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to.
In conjunction with ISO 1452-1, ISO 1452-2, ISO 1452-3 and ISO 1452-4, it is applicable to joints and assemblies with components of PVC‑U, other plastics and non-plastics materials intended to be used for the following:
- water mains and services buried in ground;
- conveyance of water above ground for both outside and inside buildings;
- buried and above-ground drainage and sewerage under pressure;
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to components for the conveyance of water and waste water up to and including 45 °C.

  • Standard
    21 pages
    English language
    sale 10% off
    e-Library read for
    1 day

This part of ISO 1452 specifies the characteristics of fittings made from unplasticized poly(vinyl chloride) (PVC-U) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to in this part of ISO 1452. In conjunction with ISO 1452-1, ISO 1452-2 and ISO 1452-5, it is applicable to PVC-U fittings and to joints with components of PVC-U, other plastics and non-plastics materials intended to be used for the following: a) water mains and services buried in the ground; b) conveyance of water above ground for both outside and inside buildings; c) buried and above-ground drainage and sewerage under pressure. It is applicable to fittings in piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for waste water under pressure. This part of ISO 1452 is also applicable to components for the conveyance of water and waste water up to and including 45 °C. For temperatures between 25 °C and 45 °C, Figure A.1 of ISO 1452-2:2009 applies.

  • Standard
    45 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 1452-4:2009 specifies the characteristics of valves made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above-ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to.
In conjunction with ISO 1452-1, ISO 1452-2, ISO 1452-3 and ISO 1452-5 it is applicable to PVC‑U valves with components of PVC-U, other plastics and non-plastics materials intended to be used for the following:
- water mains and services buried in ground;
- conveyance of water above ground for both outside and inside buildings;
- buried and above-ground drainage and sewerage under pressure.
It is applicable to valves in piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to valves for the conveyance of water and waste water up to and including 45 °C.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 22391-2:2009 specifies the characteristics of pipe made of polyethylene of raised temperature resistance (PE-RT), Type I and polyethylene of raised temperature resistance (PE-RT), Type II intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not the water is intended for human consumption (domestic systems) and for heating systems, under the design pressures and temperatures appropriate to the class of application according to ISO 22391-1.
ISO 22391-2:2009 covers a range of service conditions (classes of application), design pressures and pipe dimension classes, and also specifies test parameters and test methods. When used in conjunction with the other parts of ISO 22391, it is applicable to PE-RT pipes, fittings, their joints, and to joints having components of PE-RT, as well as of other plastics and non-plastics materials, respectively, used for hot and cold water installations.
It is applicable to pipes with or without a barrier layer or layers.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 22391-3:2009 specifies the characteristics of fittings for piping systems made of polyethylene of raised temperature resistance (PE-RT), Type I and polyethylene of raised temperature resistance (PE-RT), Type II, intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not the water is intended for human consumption (domestic systems) and for heating systems, under the design pressures and temperatures appropriate to the class of application according to ISO 22391-1.
ISO 22391-3:2009 covers a range of service conditions (classes of application), design pressures and pipe dimension classes, and also specifies test parameters and test methods. In conjunction with the other parts of ISO 22391, it is applicable to fittings made of PE-RT, as well as to those made of other materials, intended to be fitted to pipes conforming to ISO 22391-2 for hot and cold water installations, the joints of which are in accordance with ISO 22391-5.
It is applicable to the following types of fitting:
- mechanical fittings;
- socket fusion fitting;
- electrofusion fittings;
- fittings with incorporated inserts.

  • Standard
    22 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 1452-2:2009 specifies the characteristics of solid-wall pipes made from unplasticized poly(vinyl chloride) (PVC‑U) for piping systems intended for water supply and for buried and above ground drainage and sewerage under pressure. It also specifies the test parameters for the test methods referred to.
In conjunction with ISO 1452-1 and ISO 1452-5, it is applicable to extruded PVC‑U pipes without a socket and pipes with a socket (integral or not), intended to be used for the following:
- water mains and services buried in the ground;
- conveyance of water above ground for both outside and inside buildings;
- buried and above ground drainage and sewerage under pressure.
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water) intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to pipes for the conveyance of water and waste water up to and including 45 °C and to a range of pipe sizes and pressure classes. It gives requirements concerning colours.

  • Standard
    31 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 22391-1:2009 specifies the general characteristics of piping systems made of polyethylene of raised temperature resistance (PE‑RT), Type I and polyethylene of raised temperature resistance (PE-RT), Type II intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not the water is intended for human consumption (domestic systems) and for heating systems, under specified design pressures and temperatures appropriate to the class of application.
ISO 22391-1:2009 covers a range of service conditions (classes of application), design pressures and pipe dimension classes, and also specifies test parameters and defines terms. In conjunction with the other parts of ISO 22391, it is applicable to PE-RT pipes, fittings, their joints and to joints having components of PE-RT, as well as of other plastics and non-plastics materials, respectively, used for hot and cold water installations.

  • Standard
    17 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 22391-5:2009 specifies the characteristics of the fitness for purpose of piping systems made of polyethylene of raised temperature resistance (PE-RT), Type I and polyethylene of raised temperature resistance (PE-RT), Type II, intended to be used for hot and cold water installations within buildings for the conveyance of water, whether or not the water is intended for human consumption (domestic systems) and for heating systems, under the design pressures and temperatures appropriate to the class of application according to ISO 22391-1.
ISO 22391-5:2009 covers a range of service conditions (classes of application), design pressures and pipe dimension classes, and also specifies test parameters and test methods. In conjunction with the other parts of ISO 22391, it is applicable to PE-RT pipes, fittings, their joints, and to joints having components of PE-RT as well as of other plastics and non-plastics materials, respectively, used for hot and cold water installations.

  • Standard
    16 pages
    English language
    sale 10% off
    e-Library read for
    1 day

ISO 1452-1:2009 specifies the general aspects of unplasticized poly(vinyl chloride) (PVC‑U) solid-wall piping systems intended for water supply and for buried and above ground drainage and sewerage under pressure.
In conjunction with ISO 1452-2, ISO 1452-3, ISO 1452-4 and ISO 1452-5, it is applicable to PVC‑U pipes, fittings, valves and ancillary equipment, their joints and to joints with components of other plastics and non-plastics materials intended to be used for the following:
- water mains and services buried in the ground;
- conveyance of water above ground for both outside and inside buildings;
- buried and above ground drainage and sewerage under pressure.
It is applicable to piping systems intended for the supply of water under pressure up to and including 25 °C (cold water), intended for human consumption and for general purposes as well as for waste water under pressure. It is also applicable to components for the conveyance of water and waste water up to and including 45 °C.

  • Standard
    19 pages
    English language
    sale 10% off
    e-Library read for
    1 day